Doctor&Cols — colectivo de mentoría dental
Producción científica2016· Odontology

Stress distribution in the transitional peri-implant bone in a single implant-supported prosthesis with platform-switching under different angulated loads

Q2 · DentistryImpact Factor · 1.947

AutoresÁngel Álvarez‐Arenal, Luis Segura-Mori, Ignacio González-González, Hector deLlanos‐Lanchares, Fernando Sánchez Lasheras, Joseba Ellacuria-Echevarria

Por qué importa

Este estudio investiga la distribución de tensiones en el hueso peri-implantar de transición en prótesis fijas unitarias soportadas por implantes, comparando el efecto del switching de plataforma bajo cargas anguladas. Se empleó un análisis por elementos finitos tridimensional para evaluar dos modelos: uno con switching de plataforma y otro convencional. Los resultados indican que el switching de plataforma reduce las tensiones en el hueso cortical de transición, aunque las aumenta en el hueso trabecular de transición. Se observó un incremento de la tensión en el hueso cortical con la angulación de la carga, mientras que en el hueso trabecular del modelo convencional se produjo una ligera reducción. La localización de las tensiones fue similar en ambos modelos. Comprender estas diferencias es relevante para optimizar el diseño de las prótesis y la selección de las plataformas de los implantes, buscando minimizar el estrés en zonas críticas para favorecer la longevidad de los tratamientos implantosoportados.

Temas tratados

Abstract original

A 3D finite element analysis was conducted to evaluate and compare the stress distribution in the peri-implant bone (transitional cortical and trabecular bone) of one single implant-supported crown with platform switching and another without platform switching, under a vertical and an oblique load. Two models were created, simulating an osseointegrated implant (4 × 13 mm, platform 4.1 mm) embedded in the jaw bone. One model simulated a 4.1-mm diameter abutment connection (conventional model) and the other a 3.8-mm diameter abutment connection (platform-switching model). A crown with a Co-Cr alloy framework and feldspathic porcelain veneering was applied over the titanium abutment. Static, vertical and oblique loads (0°, 15°, 30°, 45°) with a maximum value of 150 N were applied to the crown. For any inclination of the applied load, the stress values in the transitional cortical bone were lower in the platform-switching model than in the conventional model. However, the stress in the transitional trabecular bone was higher in the platform-switching model than in the conventional model. Stress values increased when the load was more oblique at the transitional cortical bone in both models and was slightly reduced at the transitional trabecular bone of the conventional model. The platform-switching technique reduces the stress at the transitional cortical bone. In both models, this stress gradually increases as the load becomes more inclined. The transitional trabecular bone shows lower stress values than the transitional cortical bone. The location of stress is similar in both models.

Autor Doctor&Cols

Cómo citar

Álvarez‐Arenal Á, Segura-Mori L, González-González I, deLlanos‐Lanchares H, Lasheras FS, Ellacuria-Echevarria J. Stress distribution in the transitional peri-implant bone in a single implant-supported prosthesis with platform-switching under different angulated loads. Odontology. 2016. doi:10.1007/s10266-016-0237-6

Casos clínicos relacionados

Más producción científica del autor

Ver toda la producción científica →
Educational Partners