Doctor&Cols — colectivo de mentoría dental
Producción científica2024· Clinical Implant Dentistry and Related Research

Ultrasonography‐Guided Dental Implant Surgery: A Feasibility Study

AutoresPaolo Nava, Hamoun Sabri, Javier Calatrava, Jacob Martin Zimmer, Zhaozhao Chen, Junying Li, Hom‐Lay Wang

Por qué importa

Un estudio de viabilidad explora el uso de la ecografía para guiar la planificación y colocación de implantes dentales, ofreciendo una alternativa no ionizante a los protocolos convencionales basados en tomografía computarizada de haz cónico (CBCT). La investigación evaluó la precisión de las guías quirúrgicas diseñadas a partir de imágenes ecográficas y escaneos intraorales, comparando las posiciones planificadas con las obtenidas intraoperatoriamente. Los resultados indican que la técnica es factible, con desviaciones aceptables entre los planificaciones y la posición final de los implantes. Esta aproximación podría optimizar los procedimientos quirúrgicos, especialmente en casos donde la radiación ionizante es una preocupación, abriendo nuevas vías para la implantología asistida por imagen.

Temas tratados

Abstract original

OBJECTIVE: To evaluate the feasibility of ultrasound-image-based computer-assisted implant planning and placement. MATERIALS AND METHODS: Intraoral scans, cone-beam computerized tomography (CBCT), and ultrasound (US) scans with a custom positioning device were acquired in nine patients. Prosthetic-driven surgical guides were planned and fabricated based on ultrasound images and intraoral scans. Implants were then placed. Postoperative implant position was obtained intra-surgically by intraoral scan. Aside from the ultrasound-based plan, conventional implant planning was performed by the same operator on a pre-surgical CBCT for comparison. Linear deviations between ultrasound and CBCT-planned implant positions were measured and compared with the intra-surgical implant position, and the position deviations between two consecutive plannings were performed on the same CBCT by the same operator. The linear deviation between the 3D scan surface of the edentulous region and the ultrasonographic soft tissue profile segmentation was also assessed with reverse-engineering software. Means, standard deviations, and root mean square differences (RMSD) were calculated for every variable. RESULTS: All the ultrasound-planned implants were successfully placed, and no complications were recorded. The mean deviations in angles, shoulders, and apexes were 5.27 ± 1.75° (RMSD: 5.53°), 0.92 ± 0.26 mm (RMSD: 0.95 mm), and 1.41 ± 0.61 mm (RMSD: 1.53 mm), respectively, between the US and CBCT-planned implants; 2.63 ± 0.43° (RMSD: 2.66°), 1.16 ± 0.30 mm (RMSD: 1.19 mm), and 1.26 ± 0.27 mm (RMSD: 1.28 mm) between the planned implant and intra-surgically recorded positions; and 2.90 ± 1.36° (RMSD: 3.18°), 0.65 ± 0.27 mm (RMSD: 0.70 mm), and 0.99 ± 0.37 mm (RMSD: 1.05 mm) between two consecutive CBCTs planning performed by the same operator. The mean deviation between the 3D surfaces of model scans and ultrasound-derived soft tissue profile in the edentulous area was 0.19 ± 0.08 mm. CONCLUSIONS: Ultrasound-guided implant surgery represents a feasible non-ionizing alternative to conventional static guided implant surgical protocols for implant placement in sites with favorable characteristics.

Autor Doctor&Cols

Cómo citar

Nava P, Sabri H, Calatrava J, Zimmer JM, Chen Z, Li J, et al. Ultrasonography‐Guided Dental Implant Surgery: A Feasibility Study. Clinical Implant Dentistry and Related Research. 2024. doi:10.1111/cid.13401

Casos clínicos relacionados

Más producción científica del autor

Ver toda la producción científica →
Educational Partners